Endress+Hauser Hydrostatic Level measurement Deltapilot FMB51
Pressure sensor with the Contite measuring cell for hydrostatic level measurement
Description
Pressure sensor with the Contite measuring cell for hydrostatic level measurement
Specifications
| Pressure measuring range | 100 mbar…10 bar (1.5 psi…150 psi) |
|
Process pressure /
max. overpressure limit
|
40 bar (600 psi) |
| Accuracy | Standard 0.2% Optional 0.1% |
| Main wetted parts | Alloy C 316L optional coating AuPt |
| Process temperature | -10°C…85°C (14°F…212°F) |
| Max. measurement distance | 100m (328ft) H2O |
| Material process membrane | 316L, AlloyC Gold-Rhodium |
| Measuring cell | 100 mbar…10 bar (1.5 psi…150 psi) |
| Field of application | The Deltapilot FMB51 is a rod version with a fixed process connection. This device with the Contite measuring cell and is typically used in the environmental industry. It is made for level measurement in liquid and paste-like media in open or closed containers and is unaffected by possible foam formation. For use in SIL2 safety systems. |
| For level measurement. | |
| Process connections | Threads and flanges |
| Temperature | -10 to +85°C (14°F…185° F) |
| Measuring range | 0.1 to 10bar / 100m H2O (1.5 to 150psi / 300ft H2O) |
| Accuracy | ±0.2%, ±0.1% (option) |
| International explosion protection certificates | overfill prevention WHG, SIL, drinking water approval |
| Benefits |
Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.2%, optionally ±0.1% and minimum temperature effects
Modular concept for easy replacement of display or electronics
Seamless and independent system integration (HART/PA/FF)
Easy and safe menu-guided operation: On-site via display module, via 4 to 20mA with HART, via PROFIBUS PA, via FOUNDATION Fieldbus
International usage thanks to a wide range of approvals
|