Endress+Hauser Hydrostatic Level measurement Deltapilot FMB51
Pressure sensor with the Contite measuring cell for hydrostatic level measurement
Description
Pressure sensor with the Contite measuring cell for hydrostatic level measurement
Specifications
Pressure measuring range | 100 mbar…10 bar (1.5 psi…150 psi) |
Process pressure /
max. overpressure limit
|
40 bar (600 psi) |
Accuracy | Standard 0.2% Optional 0.1% |
Main wetted parts | Alloy C 316L optional coating AuPt |
Process temperature | -10°C…85°C (14°F…212°F) |
Max. measurement distance | 100m (328ft) H2O |
Material process membrane | 316L, AlloyC Gold-Rhodium |
Measuring cell | 100 mbar…10 bar (1.5 psi…150 psi) |
Field of application | The Deltapilot FMB51 is a rod version with a fixed process connection. This device with the Contite measuring cell and is typically used in the environmental industry. It is made for level measurement in liquid and paste-like media in open or closed containers and is unaffected by possible foam formation. For use in SIL2 safety systems. |
For level measurement. | |
Process connections | Threads and flanges |
Temperature | -10 to +85°C (14°F…185° F) |
Measuring range | 0.1 to 10bar / 100m H2O (1.5 to 150psi / 300ft H2O) |
Accuracy | ±0.2%, ±0.1% (option) |
International explosion protection certificates | overfill prevention WHG, SIL, drinking water approval |
Benefits |
Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.2%, optionally ±0.1% and minimum temperature effects
Modular concept for easy replacement of display or electronics
Seamless and independent system integration (HART/PA/FF)
Easy and safe menu-guided operation: On-site via display module, via 4 to 20mA with HART, via PROFIBUS PA, via FOUNDATION Fieldbus
International usage thanks to a wide range of approvals
|