Endress+Hauser LNGmass Coriolis flowmeter

Refueling application flowmeter with easy system integration

Category:
Description

Refueling application flowmeter with easy system integration

Specification

Measuring principle Coriolis
Product headline
A flowmeter designed for refueling applications, offering seamless system integration and accurate measurement of cryogenic gases.
Sensor features Ensure excellent operational safety with reliable performance even under extreme ambient conditions. This flowmeter reduces the need for process measuring points by offering multivariable measurement capabilities, including flow, density, and temperature. Its space-saving design eliminates the requirement for inlet and outlet runs. Capable of measuring flow rates up to 18,000 kg/h (660 lb/min), it can handle medium temperatures as low as -196 °C (-321 °F), making it suitable for a wide range of demanding industrial applications.
Transmitter features Compact and space-saving transmitter design that offers full functionality within a minimal footprint. Enjoy fast commissioning with pre-configured devices and automatic data recovery for servicing convenience. The transmitter features a robust and compact housing, ensuring durability in various industrial environments. It supports Modbus RS485 communication protocol for seamless integration into control systems.
Nominal diameter range DN 8 to 25 (⅜ to 1″)
Wetted materials Measuring tubes: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow
Max. measurement error Mass flow (liquid): ±0.15 %
Volume flow (liquid): ±0.15 %
(Reference condition)
Measuring range 0 to 18 000 kg/h (0 to 660 lb/min)
Max. process pressure PN 40, Class 300
Medium temperature range –196 to +125 °C (–320 to +257 °F)
Ambient temperature range –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material AlSi10Mg, coated
Degree of protection IP66/67, type 4X enclosure
Display/Operation No local operation
Configuration via operating tools possible
Outputs None
Inputs None
Digital communication Modbus RS485
Power supply DC 20 to 30 V
Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, EAC
Other approvals and certificates 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
CRN
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Material certificates 3.1 material

Download