Endress+Hauser Proline Promag H 10 electromagnetic flowmeter

Flowmeter for basic hygienic applications with easy-to-use operation concept

Category:
Description

Flowmeter for basic hygienic applications with easy-to-use operation concept

Specification

Measuring principle Electromagnetic
Product headline
Flowmeter for Basic Hygienic Applications with Easy-to-Use Operation
Designed for applications with sanitary requirements.
Sensor features Flexible Installation with Numerous Hygienic Process Connections
Energy-Saving Flow Measurement with No Pressure Loss
Maintenance-Free Design with No Moving Parts
Liner Material: PFA
Sensor Housing: Stainless Steel (3-A, EHEDG)
Wetted Materials CIP-/SIP-Cleanable
Transmitter features Optimum Usability with Display Touch Screen or Mobile App
Simple, Time-Saving Commissioning with Guided Parameterization
Integrated Verification with Heartbeat Technology
System Integration: HART, Modbus RS485, IO-Link
Flexible Operation with App and Optional Display
Nominal diameter range DN 2 to 150 (¹⁄₁₂ to 6″)
Wetted materials Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
Seals: aseptic molded seal (EPDM, FKM, silicone)
Measured variables Volume flow, temperature, conductivity, mass flow, corrected volume flow, corrected
conductivity
Max. measurement error Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Measuring range 0.06 dm³/min to 600 m³/h (0.015 to 2650 gal/min)
Max. process pressure PN 40, Class 150, 20K
Medium temperature range –20 to +150 °C (–4 to +302 °F)
Ambient temperature range –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material AlSi10Mg, coated
Degree of protection Standard: IP66/67, type 4X enclosure
Display/Operation 2.4″ LCD display with touch & auto rotate; Configuration and operation via SmartBlue App (Bluetooth) possible
Outputs 4-20 mA HART (active/passive), Pulse/frequency/switch output
Modbus RS485, 4-20 mA
Inputs None
Digital communication HART, MODBUS RS485
Power supply DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals CSA, GP, KC
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
Hygienic approvals and certificates
Sanitary approval: EHEDG, 3-A, liner and seals acc. to FDA, cGMP

Download