Specification
| Measuring principle | Electromagnetic |
| Product headline |
Flowmeter for Basic Hygienic Applications with Easy-to-Use Operation
Designed for applications with sanitary requirements.
|
| Sensor features | Flexible Installation with Numerous Hygienic Process Connections Energy-Saving Flow Measurement with No Pressure Loss Maintenance-Free Design with No Moving Parts Liner Material: PFA Sensor Housing: Stainless Steel (3-A, EHEDG) Wetted Materials CIP-/SIP-Cleanable |
| Transmitter features | Optimum Usability with Display Touch Screen or Mobile App Simple, Time-Saving Commissioning with Guided Parameterization Integrated Verification with Heartbeat Technology System Integration: HART, Modbus RS485, IO-Link Flexible Operation with App and Optional Display |
| Nominal diameter range | DN 2 to 150 (¹⁄₁₂ to 6″) |
| Wetted materials | Liner: PFA Electrodes: 1.4435 (316L); Alloy C22 Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve Seals: aseptic molded seal (EPDM, FKM, silicone) |
| Measured variables | Volume flow, temperature, conductivity, mass flow, corrected volume flow, corrected conductivity |
| Max. measurement error | Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s) |
| Measuring range | 0.06 dm³/min to 600 m³/h (0.015 to 2650 gal/min) |
| Max. process pressure | PN 40, Class 150, 20K |
| Medium temperature range | –20 to +150 °C (–4 to +302 °F) |
| Ambient temperature range | –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant |
| Transmitter housing material | AlSi10Mg, coated |
| Degree of protection | Standard: IP66/67, type 4X enclosure |
| Display/Operation | 2.4″ LCD display with touch & auto rotate; Configuration and operation via SmartBlue App (Bluetooth) possible |
| Outputs | 4-20 mA HART (active/passive), Pulse/frequency/switch output Modbus RS485, 4-20 mA |
| Inputs | None |
| Digital communication | HART, MODBUS RS485 |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | CSA, GP, KC |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates |
Sanitary approval: EHEDG, 3-A, liner and seals acc. to FDA, cGMP |