Endress+Hauser Proline Promag P 100 electromagnetic flowmeter
The flowmeter for highest medium temperatures with an ultra-compact transmitter
Category: E+H
Description
The flowmeter for highest medium temperatures with an ultra-compact transmitter
Specification
| Measuring principle | Electromagnetic |
| Product headline | The Highest Temperature Flowmeter with Ultra-Compact Transmitter
Designed for chemical and process applications with corrosive liquids and high medium temperatures. |
| Sensor features | Diverse Applications with Variety of Wetted Materials Energy-Saving Flow Measurement with No Pressure Loss Maintenance-Free Design with No Moving Parts Max. Nominal Diameter: DN 600 (24″) Common Ex Approvals Liner Options: PTFE or PFA |
| Transmitter features | Space-Saving Transmitter with Full Functionality Time-Saving Local Operation via Integrated Web Server Integrated Verification with Heartbeat Technology Robust, Ultra-Compact Transmitter Housing Local Display Available |
| Nominal diameter range | DN 15 to 600 (½ to 24″) |
| Wetted materials | Liner: PFA, PTFE Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium Duplex 1.4462 (UNS S31803) |
| Measured variables | Volume flow, conductivity, mass flow, corrected volume flow, corrected conductivity |
| Max. measurement error | Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s) Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s) |
| Measuring range | 4 dm³/min to 9600 m³/h (1 to 44 000 gal/min) |
| Max. process pressure | PN 40, Class 300, 20K |
| Medium temperature range | Liner material PFA: –20 to +150 °C (–4 to +302 °F) Liner material PFA high‐temperature: –20 to +180 °C (–4 to +356 °F) Liner material PTFE: –40 to +130 °C (–40 to +266 °F) |
| Ambient temperature range | Flange material carbon steel: –10 to +60 °C (+14 to +140 °F) Flange material stainless steel: –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | DN 15 to 300 (½ to 12″): AlSi10Mg, coated DN 350 to 600 (14 to 24″): Carbon steel with protective varnish |
| Transmitter housing material | AlSi10Mg, coated |
| Degree of protection | IP66/67, type 4X enclosure |
| Display/Operation | 4‐line backlit display available (no local operation) Configuration via web browser and operating tools possible |
| Outputs | 4‐20 mA HART (passive) Pulse/frequency/switch output (passive) |
| Inputs | None |
| Digital communication | HART, PROFIBUS DP, Modbus RS485, EtherNet/IP, PROFINET |
| Power supply | DC 20 to 30 V |
| Hazardous area approvals | ATEX, IECEx, cCSAus, INMETRO |
| Product safety | CE, C-tick |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates |
Drinking water approval: ACS, NSF 61, WRAS |